Turbo-Lux® 3

Fire pump test meter with three approvals: FM, LPCB and VdS

The Turbo-Lux® 3 is the world’s first and only fire pump test meter approved by all three test institutes (FM, LPCB and VdS). Large corporations and global companies in particular can benefit accordingly from a uniform international solution for their fire safety systems.

Special becomes standard – now all dimensions are available with shorter inlet and outlet sections.

Article number
Dimmension
Diameter (mm)
Measuring range G (USgpm)
Measuring range l (lpm)
Nominal power
Approval
Price*
TL3A0-LP
Version: 1
Dimensions: DN 200 8"
Diameter: 219,10
Measuring range (G) USgpm: 600 ... 3000
Measuring range (L) lpm: 2200 ... 11000
Nominal power: 1500
Approvals:
  • FM
  • LPCB
  • VdS
846.82 
TL3A0-LQ
Version: 1
Dimensions: DN 200 8"
Diameter: 219,10
Measuring range (G) USgpm: 800 ... 4000
Measuring range (L) lpm: 3000 ... 15000
Nominal power: 2000
Approvals:
  • FM
  • LPCB
  • VdS
846.82 
TL3A0-LR
Version: 1
Dimensions: DN 200 8"
Diameter: 219,10
Measuring range (G) USgpm: 1000 ... 5000
Measuring range (L) lpm: 3800 ... 19000
Nominal power: 2500
Approvals:
  • FM
  • LPCB
  • VdS
846.82 
TL3A0-LS
Version: 1
Dimensions: DN 200 8"
Diameter: 219,10
Measuring range (G) USgpm: 1200 ... 6000
Measuring range (L) lpm: 4500 ... 22000
Nominal power: 3000
Approvals:
  • FM
  • LPCB
  • VdS
846.82 

*incl. VAT.

Accessories

Article number
Product
Price*
ZB-TL3P0-001
Replacement cap
36.32 
ZB-TL3P0-002
Replacement cap - stainless steel
52.06 

*incl. VAT.

Areas of application:

The Turbo-Lux 3 orifice flow meter is used to measure the volume of water in closed pipelines. The installation position and direction of flow are flexible. The areas of application focus on use in stationary water-based extinguishing systems in water supply test pipes. The certifications required form FM, LPCB and VdS have been obtained.

The orifice fire pump test meter is used in the following industries:

  • Fire safety (stationary sprinkler systems)

Advantages of the fire pump test meter:

  • Safety certified by three independent certification companies in just one device (FM, LPCB and VdS)
  • Nominal sizes from DN 50 (2") to DN 300 (12")
  • Covers pump rates from 50 ... 5.000 USgpm (185 ... 19.000 lpm)
  • Covers measuring ranges from 20 ... 10.000 USgpm (75 ... 38.000 lpm)
  • Easy to install with grooved connection to the pipe network
  • Thanks to the sophisticated design, the device is ready for operation after connection to the pipe network with just one threaded connection, guaranteeing rapid and simple installation
  • The only manufacturer with a VdS approval offering groove connections
  • High and constant read precision
  • Flexible installation location, installation position and direction of flow
  • Not susceptible to vibrations
  • Robust and low maintenance design
  • Reliable and long service life
  • Calibration certificate (optional)
  • Available at short notice

Measuring tube connections:

  • Groove connection DN 50 - DN 300 / 2" – 12" 

 

  • Calibrating measuring devices
  • Maintenance and servicing
  • Provision of tender texts
  • Provision of technical component drawings for implementing the devices in fire safety systems

 

FAQ - Fire Pump Test Meter - Turbo-Lux® 3

Where can test certificates be downloaded subsequently?

Via our homepage – under the following link you can find the instructions how to do this:

 

Is the Turbo-Lux 3 also available with a flange connection?

No - but there is the option of ordering an additional folding flange adapter to mount the Turbo-Lux 3 into a pipe with flanges.


Arrange a consultation appointment

If you still have questions or need a special solution, please call or write us!

We look forward to receiving your contact and will be happy to call you back.

Schedule a Consultation!

Your contact person:

Madita Widmann
Sales

P: +49 (0)2237 60006-48

Portät
Portät

Michael Jüch
Technology

P: +49 (0)2237 60006-14

Follow us on linkedin Follow us on LinkedIn